Refrigeration and Air Conditioning Lab


Window Type Air Conditioner Test Rig Ice Plant Tutor (20 Kgs Capacity) Air Conditioning Test Rig Cold Storage Test Rig
Mechanical Heat Pump Test Rig Air Washer Test Rig Air Washer Test Rig Cooling Tower Test Rig Refrigeration Test Rig



Window Type Air Conditioner Test Rig
Aim :
This Laboratory scale working model housed on a M.S. Square tube frame further mounted on a wheels (CI) with nstrumentation panel is used i) To study the Vapour compression Cycle ii) To calculate co-efficient of performance (COP) iii) To evaluate tonnage capacity.
01.Hermitically Sealed Compressor
02. Air Cooled Condenser : 1 NO.
03. Condenser Cooling Fan : 1 NO.
04.Rota Meter (refrigerant R 22) : 1 No
05.Charging Valves : ¼”
06.Filter Drier : DM 50, (3/8”)
07. Energy Meter : 1 NO.
08.Pressure / Compound Gauges : 1 NO. each
a) Range : 0 to 300 psi / 30 “ Hg to +150 psi
09. Measuring Instruments
a)Digital Temperature Indicator : Ambient to 199.9 Deg.c.
b)Anemometer  
10. Air Conditioning Kit : 1 SET
OPTIONAL: AT EXTRA COST
LINE VOLTAGE CORRECTOR
 
Capacity : 4KVA
Output : 230V+/- 10%


Ice Plant Tutor (20 Kgs Capacity)
Aim :
This Laboratory scale working model housed on a M.S. Angle frame further mounted on a wheels with instrumentation panel is used to determine i) The working of ICE Plant ii) Co-efficient of performance (COP) and iii) Refrigeration circuit.
01. Hermitically Sealed Compressor
Make : Tecumesh/Kirloskar
02. Air Cooled Condenser : 12 x 13 x 2 row
03. Fan Motor :
a) Capacity : 1/83 HP
b) Make : AUE
04. Hand Shut Of Valves
a) Size : ¼ ”
05. Filter Drier  
a) Make : Danfoss
06. Energy Meters
Make : Bentex/equivalent
07. Stirrer  
a) Make : Remi/Tullu
08. Pressure/ Compound Gauges
Range : 0 to 300 psi/-30” Hg to +150psi
09. Brine Tank : Stainless steel tank of 304 grade
10. Evaporator cooling coil : 3/8” Copper with accumulator
11. Ice Cans : GI / 4 Nos
12. Voltage stabilizer : 2KVA
Note: The equipment will be self-contained in all respect except for Electric power / Water supply wherever necessary to be provided by the purchaser.

Air Conditioning Test Rig
Aim :
This Laboratory scale working model housed on a M.S. Square tube frame further mounted on a wheels (CI) with instrumentation panel is used i) To study the Vapour Compression Cycle ii) To calculate co-efficient to performance (COP) iii) To evaluate tonnage capacity iv) To study humidification and dehumidification.
01. Hermitically Sealed Compressor
Capacity : 1.0 Ton
02. Air Cooled Condenser
Capacity : 1.0 Ton
03. Condenser Cooling Fan
Capacity : 1/10 HP
04. Rota Meter (Refrigerant R 22) 1 No
05. Hand Shut Off Valves
Size : 3/8 & 1/4”
06. Filter Drier : DM 50 (3/8 )” Type
07. Energy Meters : 2 NO.
08. Thermostat : 1 NO
09. Pressure/ Compound Gauges
1 Nos Each. Range : 0 to 300 psi/-30” Hg to + 150 Psi
10. Measuring Instruments
a) Digital Temperature Indicator : Ambient to199.9deg. c.
11. Finned Heater : 1 NO.
12. Electronic Dimmer : 1 NO
13. Hp/Lpcutout : 1 NO.
14. Air Conditioning Duct : 1 SET
15. Steam Generator : 1 SET
16. Anemometer : 1 NO.
Optional : At Extra Cost Line Voltage Corrector
Capacity : 4KVA
Output : 230V+/- 10%


Cold Storage Test Rig
Aim :
This Laboratory scale working model housed on a M.S. Square tube frame and further mounted on a wheels(CI) with instrumentation panel is used. i) To study the vapor compression refrigeration cycle ii) To calculate Co-efficient of performance (C.O.P.)
01. Hermitically Sealed Compressor
Capacity : 1/3 TON
02. Air Cooled Condenser
Capacity : 1/2 HP
03. Condenser Cooling Fan
Capacity : 1/83 HP
04. Rotameter (Referigerant R 12) : 1 No
05. Cold Storage Cabinet : 5 Cft With Insulation
06. Filter Drier : DM 50 (1/4”)
07. Energy Meter : 1 NO
08. Thermostatic Expansion Valve : 1 NO.
09. Pressure / Compound Gauges : 1 NO. each
Range : 0 to 300 psi /- 30 “ Hg to 150 psi
10. Measuring Instruments
Digital Temperature Indicator :-30 to 199.9 deg.c.
Optional : At Extra Cost Line Voltage Corrector
Capacity : 2KVA
Output : 230V+/- 10%


Mechanical Heat Pump Test Rig
Aim :
This Laboratory scale working model housed on a M.S. Square tube frame and further mounted on a wheels (CI) with instrumentation panel is used i) To study the performance of vapour compression Refrigeration system using water cooled condenser / water cooled evaporator, ii) Co efficient of performance (COP) of the system.
01. Hermitically Sealed Compressor
Capacity : 1/3 HP
Make & Model : SHRIRAM/KIRLOSKAR
02. Condenser
Type : Shell and Coil with Refrigerant inside the tube
03. Evaporator Water Cooled
Type : Shell and Coil with refrigerant Inside the tube
04. ROTA METER : 1 No
Make : Eureka
05. Hand Shut Off Valves
Size : ¼”
Make : Kim/vanaz/equivalenT
06.Filter Drier
Make : Danfoss/equivalent
07. Energy Meters
Make : Bhel/indimeter/equivalent
08. Thermostat
Make : Danfoss/equivalent
09. Compound Gauges : 1 NO
Range : -30 “ Hg to +150 psi
Make : Fiebig/equivalent
10. Measuring Instruments
a) Digital Temperature Indicator  
11. Sump Tank
a) Capacity : Suitable
b) Material : S.S
12. PUMP
a) Make : UP National Mgf. Co.,/ Equivalent
13. Rota Meter
Make : Eureka/ Equivalent
Optional : At Extra Cost Line Voltage Corrector
Capacity : 4KVA
Output : 230V+/- 10%


Air Washer Test Rig
Aim :
To treat the air by humidifying Or by dehumidifying it to the required comfort.
AIR WASHER SECTION:
Refrigeration Systems:
Will be corporate with compressor, condenser filter drier, and condenser fan motor, capillary expansion. The system will be controlled through temperature indicator cum controller for both heating and cooling and the station temperature can be read from wet and dry bulb temp and also with 'k' type thermocouple, the velocity of air will be arrived through anemometer. The above unit is self-contained in all respect except power and water facility.

Cooling Tower Test Rig
Aim :
This Laboratory scale working model housed on a M.S. Square tube frame along with instrumentation panel is used To determine i) the tower characteristic (KVA/L Value), ii) The made up water flow rate and iii) To plot end states on a psychometric chart which can be used to draw energy balance.
01. Cooling Tower
a) Size : 250 x 250 mm
b) Height : 1000 mm
c) Material : Aluminum body with acrylic frame
D) Packing Sheets : Perforated Aluminum corrugated
02. Blower
a. Capacity : 1HP
b. Make : Any reputed make.
03. Geyaser
a. Capacity : 3KW
b. Make : RACOLD/ BAJAJ
04. Psychometrics Gun
a) Material : Acrylic
05. Digital Temperature Indicator:
a. No. of Digits : 4 Digits
b. Range : Ambient to 200
c. Resolution  
06. Thermocouples
a) Length : 1 Mtr.
b) Type : Cr. Al
c) Sheathing : Wire mesh sheathing
07. Air Flow measurement : U Tube Manometer
a. Material : Glass
b. Size : 300mm
c. Media : Mercury
08. Water flow measurement : Rotameter
a. Range : 0 to 60 cc/sec
09. Calibrated water tank
a. Material : S.S/18 Swg
b. Size : 200 x 250
10. Starter
a. Make : Crompton/Any Reputed Make.


Refrigeration Test Rig
Aim :
This Laboratory scale working model housed on a M.S. Square tube frame and further mounted on a wheels (CI) with instrumentation panel is used i) To study the vapor compression refrigeration cycle ii) To calculate Co-efficient of performance (COP).
01. Hermitically Sealed Compressor
Capacity : 1/3 Ton
02. Air Cooled Condenser  
Capacity : 1/2 HP
03. Condenser Cooling Fan
Capacity : 1/83 HP
04. Rotameter
R 134a Gas (Echo Friendly Gas) : 1 No
05. Hand Shut Off Valves
Size : ¼”
06. Filter Drier : DM 50 ¼ “
07. Energy Meter : 1 NO.
08. Thermostat : 1 NO
09. Pressure/compound Gauges:
1 NO. Each Range : 0 to 300 psi/-30” Hg to+150 psi
10. Measuring Instruments
a) Digital Temperature Indicator :-30 to 199.9 deg. C.
Optional : At Extra Cost Line Voltage Corrector
Capacity : 2KVA
Output : 230V+/- 10%